Generator
Basic Reading Summary
Devices |
Voltage A-B (V) |
Current A (A) |
Real Power (kW) |
Power Factor |
Building1.Incomer |
480 |
235 |
180.722181261737 |
-92.5 |
Building2.Incomer |
480 |
220 |
162.785063098553 |
-89 |
Industrial.Incomer |
12000 |
230 |
4398.02341057889 |
-92 |
Circuit Breaker Status Summary
Devices |
Breaker Status - Closed |
Breaker Trip Status |
Current Max Present (A) |
Current Avg (A) |
Device drawn position - in |
Device drawn position - out |
Device drawn position - test |
Device drawn position - in between |
CB8_Feed1 |
1 |
0 |
235 |
232 |
1 |
0 |
0 |
0 |
CB8_Feed1 |
0 |
1 |
220 |
221 |
1 |
0 |
0 |
0 |
CB8_Feed2 |
1 |
0 |
230 |
236 |
1 |
0 |
0 |
0 |
Demand Current Summary
Devices |
Block Demand Current A Into the Load (A) |
Block Demand Current B Into the Load (A) |
Block Demand Current C Into the Load (A) |
Building1.Incomer |
220 |
220 |
220 |
Building1.Incomer |
190 |
190 |
190 |
Industrial.Incomer |
5994 |
5994 |
5994 |
Demand Voltage Summary
Devices |
Block Demand Voltage A-B (V) |
Block Demand Voltage B-C (B) |
Block Demand Voltage C-A (V) |
Building1.Incomer |
481 |
480 |
481 |
Building1.Incomer |
482 |
479 |
479 |
Industrial.Incomer |
12003 |
12041 |
12013 |
Energy Summary
Devices |
Real Energy (kWh) |
Real Energy Total (kWh) |
Reactive Energy (kVArh) |
Reactive Energy Total (kVArh) |
Building1.Incomer |
2,020,861.0 |
2,020,861.0 |
827,970.9 |
827,970.9 |
Incremental Reactive Energy Summary
Devices |
Incremental Reactive Energy Into the Load (kVArh) |
Incremental Reactive Energy Out of the Load (kVArh) |
D/T Last Incremental Energy Update |
Building1.Incomer |
827,970.9 |
0 |
12:00AM 01-01-2011 |
Building2.Incomer |
827,970.9 |
0 |
12:00AM 01-01-2011 |
Incremental Real Energy Summary
Devices |
Incremental Real Energy Into the Load (kWh) |
Incremental Real Energy Out of the Load (kWh) |
D/T Last Incremental Energy Update |
Building1.Incomer |
2,020,861.0 |
0 |
12:00AM 01-01-2011 |
Building2.Incomer |
1,022,098 |
0 |
12:00AM 01-01-2011 |
Building3.Gen1 |
0 |
650,768 |
12:00AM 01-01-2011 |
Load Current Summary
Devices |
Current A (A) |
Current B (A) |
Current C (A) |
Current Avg (A) |
Building1.Incomer |
210.9 |
223.6 |
238.2 |
224.4 |
Building2.Incomer |
223.5 |
240.8 |
239 |
234.5 |
Power Factor Summary
Devices |
Power Factor A |
Power Factor B |
Power Factor C |
Power Factor |
Building1.Incomer |
94.3 |
93.6 |
94.5 |
94.4 |
Building2.Incomer |
95.3 |
93.1 |
92.5 |
92.4 |
Power Flow Summary
Devices |
Real Power (kW) |
Reactive Power (kVAr) |
Apparent Power (kVA) |
Block Demand Real Power (kW) |
Peak Block Demand Real Power (kW) |
Block Demand Real Power Predicted (kW) |
Keating.Main_01 |
742 |
502 |
942 |
723 |
1014 |
744 |
Keating.Main_02 |
747 |
557 |
932 |
623 |
1210 |
654 |
Keating.Main_03 |
774 |
310 |
834 |
811 |
902 |
771 |
Keating.Main_04 |
358 |
274 |
483 |
384 |
643 |
402 |
Keating.Main_05 |
13 |
15 |
20 |
15 |
328 |
13 |
Keating.Main_06 |
635 |
305 |
704 |
675 |
803 |
636 |
Keating.Main_07 |
101 |
130 |
164 |
109 |
535 |
59 |
Keating.Main_08 |
212 |
69 |
223 |
213 |
389 |
212 |
Bertram.Aux_01 |
225 |
295 |
372 |
228 |
269 |
226 |
Bertram.Aux_02 |
345 |
228 |
413 |
340 |
621 |
346 |
Bertram.Aux_03 |
450 |
272 |
533 |
458 |
493 |
498 |
Bertram.Aux_04 |
762 |
557 |
344 |
751 |
795 |
752 |
Bertram.Aux_05 |
308 |
211 |
373 |
312 |
456 |
300 |
System Voltage Summary
Devices |
Voltage A-B (V) |
Voltage B-C (V) |
Voltage C-A (V) |
Voltage A-N (V) |
Voltage B-N (V) |
Voltage C-N (V) |
Building1.Incomer |
596.4 |
590.6 |
586.5 |
342.6 |
343.6 |
338.1 |
Building2.Incomer |
594.3 |
590.1 |
587.9 |
344.1 |
340.9 |
337.9 |
THD Current Summary
Devices |
THD Current A (%) |
THD Current B (%) |
THD Current C (%) |
Building1.Incomer |
4.4 |
4.6 |
3.7 |
Building2.Incomer |
5.1 |
5.5 |
5.2 |
Industrial.Incomer |
18.9 |
19.0 |
16.8 |
THD Voltage Summary
Devices |
THD Voltage A-B (%) |
THD Voltage B-C (%) |
THD Voltage C-A (%) |
THD Voltage A-N (%) |
THD Voltage B-N (%) |
THD Voltage C-N (%) |
101.zSub1 |
0.8 |
0.8 |
1.0 |
0.9 |
0.8 |
1.0 |
101.zSub2 |
1.3 |
1.1 |
1.0 |
1.2 |
1.3 |
1.0 |
101.zSub3 |
1.4 |
1.5 |
1.5 |
1.4 |
1.5 |
1.7 |
B3.zSub |
1.1 |
1.2 |
1.2 |
1.2 |
1.1 |
1.2 |
C3.zSub |
1.4 |
1.1 |
1.3 |
1.4 |
1.4 |
1.2 |
C3.zSub.A |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
F1.zSub |
1.2 |
1.3 |
1.1 |
1.1 |
1.3 |
1.2 |
F5.zEast.Sub |
1.7 |
1.7 |
1.5 |
1.9 |
1.8 |
1.7 |
F5.zLighting.Sub |
1.8 |
2.0 |
1.9 |
1.8 |
2.0 |
2.0 |
F5.zWest.Sub |
1.5 |
1.5 |
1.5 |
1.6 |
1.6 |
1.6 |
F8.zSub.P1 |
1.7 |
1.6 |
1.6 |
1.7 |
1.7 |
1.6 |
F8.zSub.P2 |
1.2 |
1.1 |
1.2 |
1.3 |
1.2 |
1.1 |
F8.zSub.P3 |
1.0 |
.9 |
.9 |
1.1 |
.9 |
1.0 |
Uptime Summary
Devices |
Uptime Percent - Last 12 Months (%) |
Uptime Last 12 Month (s) |
Downtime Last 12 Month (s) |
Building1.Incomer |
97.6 |
30799559.8 |
757366.2 |
Building2.Incomer |
97.6 |
30799559.8 |
757366.2 |
Vigilohm
Devices |
Insulation Resistance (Ohm) |
Ground Coupling Capacity (nF) |
Fault Threshold (Ohm) |
Prevention Threshold (Ohm) |
Building1.Incomer |
50,000,000 |
1000 |
50,000 |
100,000 |